{"id":96,"date":"2016-09-07T15:22:28","date_gmt":"2016-09-07T07:22:28","guid":{"rendered":"https:\/\/www.scubabest.com.tw\/?page_id=96"},"modified":"2018-03-05T16:00:00","modified_gmt":"2018-03-05T08:00:00","slug":"support","status":"publish","type":"page","link":"https:\/\/www.scubabest.com.tw\/?page_id=96","title":{"rendered":"SUPPORT"},"content":{"rendered":"<h2 style=\"text-align: center;\">INSTRUCTIONS\u00a0 FOR\u00a0 USE<\/h2>\n<p>WARNING\u2236<br \/>\nImproper use of dive instruments may result in serious injury or death.Read<br \/>\nand understand these instructions thoroughly before you dive .<br \/>\nPRESSURE GAUGE \/ SYNTHETIC CASE<br \/>\n\uff0aThe pressure gauge with H.P is made to be used with compressed air only.<br \/>\n\uff0aLink the hose at the jacket to avoid pressure gauge traverse.<br \/>\n\uff0amaximum pressure = 5,000psi(350bar)<br \/>\nTemperature= 0 to 100\u2109(-5\u00b0 to 45\u2103)<br \/>\nThread size=7\/16\u201d \u2573 20- UNF<br \/>\n\uff0aConnect the hose to the high connection of the regulator ,after preventively having anointed the O-rings with silicon grease.<br \/>\n\uff0aThe pressure gauge with H.P.hose satisfies the requisite of the European Normative specifications CE EN250.<br \/>\nPreciseness\uff1a<br \/>\nStandard of precision by CE EN 250 NORM<br \/>\n\u00b1 5bar a 50bar\u00a0\u00a0 ( \u00b1 70psi a 700psi)<br \/>\n\u00b110bar a 100bar\u00a0 ( \u00b1140psi a 1,400psi)<br \/>\n\u00b110bar a 200bar\u00a0 ( \u00b1140psi a 2,800psi)<br \/>\n\u00b110bar a 300bar\u00a0 ( \u00b1140psi a 4,200psi)<br \/>\nUpkeep\uff1a<br \/>\n\uff0aThe wear and tear subjects\u00a0 components of the pressure gauge like H.P. hose , pivot pin , O-Rings , must be periodically verified and replaced.<br \/>\n\uff0aWith the purpose to limit the deterioration of the O-Rings we recommend the periodical use of compatible lubricant.<br \/>\n\uff0aAfter the use , rinse the complete pressure gauge with fresh water and keep the instrument dry.<br \/>\nATTENTION<br \/>\n\uff0aAlways keep the pressure gauge dial away from your face when turning on your tank valve.<br \/>\n\uff0aDont use solutions to clean the glass (the raw material could lose his unbreakable characteristic).<br \/>\n\uff0aNever obstruct the one-way vent valve located on the back side of the gauge.<br \/>\n\uff0aUse two 15mm wrench to close , not forcing the link excessively.<br \/>\nDEPTH\u00a0 GAUGE<br \/>\n\uff0aThe black needle with red tip indicates current depth and as depth increases it pushes the thinner needle.<br \/>\n\uff0aTo reset the max depth thinner needle for a new dive,turn the slotted knob located in the center of the gauge face counterclockwise until it just makes contact with the black needle with the red tip.<br \/>\n\uff0asteel(copper-berylium for military) membrane system of reading that elevated sensibility and precision.<br \/>\n\uff0aDial with parabolic scale to improve the precision of reading on the various depths.<br \/>\n\uff0aDont\u00a0 expose the tool to sources of heat.<br \/>\n\uff0aThe employment over the maximum value of suitable scale on the dial can damages the tool in irremediable way.<br \/>\n\uff0aThe Depth gauge satisfies the requiste of the European Normative<br \/>\nspecifications CE EN 250,13319.<br \/>\nPreciseness\uff1a<br \/>\nStandard of precision by CE EN 250 ,13319 NORM.<br \/>\n(+0.8m.-0.4m) a 3 meter\u00a0\u00a0\u00a0 ( +2.62 ft.-1.31 ft ) a\u00a0 10 ft<br \/>\n(+0.8m.-0.4m) a 6 meter\u00a0\u00a0\u00a0 ( +2.62 ft.-1.31 ft ) a\u00a0 20 ft<br \/>\n(+0.8m.-0.8m) a 9 meter\u00a0\u00a0\u00a0 ( +2.62 ft.-2.62 ft ) a\u00a0 30 ft<br \/>\n(+1.0m.-1.2m) a 15meter\u00a0\u00a0 ( +3.28 ft.-3.93 ft ) a\u00a0 50 ft<br \/>\n(+1.0m.-1.2m) a 30meter\u00a0\u00a0 ( +3.28 ft.-3.93 ft ) a 100 ft<br \/>\n(+1.0m.-1.5m) a 45meter\u00a0\u00a0 ( +3.28 ft.-4.92 ft ) a 150 ft<br \/>\n(+1.0m.-1.5m) a 60meter\u00a0\u00a0 ( +3.28 ft.-4.92 ft ) a 200 ft<br \/>\n(+1.0m.-1.5m) a 70meter\u00a0\u00a0 ( +3.28 ft.-4.92 ft ) a 230 ft<\/p>\n<p>ATTENTION<br \/>\n\uff0aRinse the depth gauge with fresh water after dive and not employ solutions to clean the glass(the material could lose the characteristics of impermeability or transparency if put in contact with not compatible substances).<br \/>\n\uff0aDo not obstruct the depth sensor opening located on the back side of the gauge.<br \/>\n\uff0aNever over come the maximum attainable depth from the tool(equivalent to the end scale printed on the dial of the tool)<\/p>\n<p>UNDERWATER COMPASS<br \/>\n\uff0aThe compass is mainly used to follow a predetermined direction.<br \/>\nThe red line on the covert glass,points out the direction that you need to take.<br \/>\n\uff0aAlways avoid the direct expose of the tool to the sun or to sources of heat and rinse afterdive with fresh water.<br \/>\n\uff0aThe contained liquid in the compass can develop bubbles of air if exposed to sources of excessive heat.These bubbles dont invalidated the good working of the compass and they have the tendency to disappear when temperature come back to normal condition.<\/p>\n<p>WARRANTY<br \/>\nConditions of warranty\uff1a<br \/>\n\uff0a instruments have a warranty of two years from manufacturing<br \/>\ndate.(H.P hose have a warranty of one year)<br \/>\n\uff0aThe warranty covers pieces recognized faulty by our technicians for<br \/>\nmanufacturing or material defect.<\/p>\n<p>The warranty doesnt cover\uff1a<br \/>\n\uff0adamage caused by shocks , fallings or bad use in surface or<br \/>\ndive,aspect or functioning defects caused by usual products\u00a0 aging.<br \/>\n\uff0aThe warranty declines in case of products manipulation or opening<br \/>\nby person lacking of adequate technical if necessary,or product<br \/>\ntested with not adequate control equipment.<br \/>\n\uff0aThe periodical maintenance and the replacement of fatigue subject components during the use.<br \/>\n\uff0aThe maintenance and replacement of swivel and respective O-ring.<br \/>\n\uff0aThe replacement of flexible tube high pressure hose.<br \/>\n\uff0aWarranty does not extend to plastic gauge faces , rubber<br \/>\nboots , O-rings , hosefitting corrosion .<\/p>\n<p>Repair estimate :<br \/>\n\uff0aNot yet under warranty instruments will be subject to repair estimate with payment in<br \/>\nadvance.<br \/>\n\uff0aThe repair will begin only after customers confirmation to proceed and respective<br \/>\npayment.<br \/>\n\uff0aDelivery costs for instrument return,Is charged to the customer.<\/p>\n<p>Limitation of Liability<br \/>\nTo the maximum extent permitted by applicable mandatory laws, this limited warranty is<br \/>\nyour sole and exclusive remedy and is in lieu of all other warranties, expressed or implied.<br \/>\nScubabest shall not be<br \/>\nliable for special, incidental, punitive or consequential damages. Scubabest shall not be<br \/>\nliable for delay in rendering warranty service.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>&hellip;<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":3,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/www.scubabest.com.tw\/index.php?rest_route=\/wp\/v2\/pages\/96"}],"collection":[{"href":"https:\/\/www.scubabest.com.tw\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.scubabest.com.tw\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.scubabest.com.tw\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.scubabest.com.tw\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=96"}],"version-history":[{"count":3,"href":"https:\/\/www.scubabest.com.tw\/index.php?rest_route=\/wp\/v2\/pages\/96\/revisions"}],"predecessor-version":[{"id":177,"href":"https:\/\/www.scubabest.com.tw\/index.php?rest_route=\/wp\/v2\/pages\/96\/revisions\/177"}],"wp:attachment":[{"href":"https:\/\/www.scubabest.com.tw\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=96"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}